Specials

Manufacturers


  Home > Parts > Furnace Repair Parts >

Robertshaw 780-002 Universal Ignition Module Replacement Kit
Robertshaw 780-002 Universal Ignition Module Replacement Kit


 
Our Price: $166.69


Quantity in Stock:3

Product Code: ROB780-002

Same Day Processing

Your Order Processes And Ships Out The Same Day If In Stock And Ordered Before 3 PM Eastern Mon-Fri [Add $3.00]

Qty:  
Description
 
Replacement Ignition Module, Control Module for LP Gas System
Features
These kits have a lockout feature to shut off all gas to the furnace, should pilot ignition fail to occur after a predetermined time period. The 780-002 provides 3 tries for ignition, each ignition period is 90 seconds followed by a 6 minute time delay between ignition attempts. After 3 tries if no pilot flame is sensed, unit goes into lockout and must be reset at the thermostat.

  • Replaces one rod and/or two rod systems.
  • Reduces truck stock inventory, saving space and money.
  • Includes vent damper adaptor assembly.
  • Easy-to-install with complete in-depth installation instructions.
  • Replaces Robertshaw, Johnson Controls, and Honeywell

Specifications
Input Voltage 24 VAC to 50/60 Hz
Transformer 24 VAC / 20 VA
Spark rate 3 to 4 sparks per second
Pilot valve, Main valve 1 amp at .5 PF
Combined load 1.5 at .4 PF
Flame sense current .7 mA DC @ 25°C / 24 VAC
Maximum total current load 1.5 amp
Flame failure reignition time .8 seconds maximum
Thermostat anticipator setting .7 amp
Ambient temperature rating –40 to 175° (–40 to 80°C)

Manufacturer Name Part Number Repl. Type Notes
AIRFLOW SP735L Functional
ALCO FOOD PREP. SP735 Functional
BINET CORP. 97H0401 Functional
BRADFORD-WHITE 233-39762-00A Functional
CABELL IND. 7-70151 Functional
CARRIER LH33AP102 Functional
CARRIER/AIR COND.CO. P771-1039 Functional
CHAMBERLAIN CROP. 51885A Functional
ED PAC/AC MFG. 100-831-63 Functional
EDISON 100-831-62 Functional
EISCO LIMITED 100-831-60 Functional
ELECTRO-HOME 100-831-14 Functional
ELECTRO-THERM 100-831-12 Functional
ELIXIER 100-831-10 Functional
ELKAY MFG. COMPANY 100-831-07 Functional
ELLIS & WATTS 100-831-06 Exact
ELMET CORP. 100-831-05 Functional
EMBASSY INDUSTRIES 100-831-03 Exact Electronic Control
GENERAL STEEL WARES 70754 Functional
HONEYWELL R8184G 1021 Functional
HONEYWELL R8184G 1179 Functional
HONEYWELL S8600A1001 Functional
HONEYWELL S8600B1009 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8600C1015 Functional
HONEYWELL S8600H1006 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8600H1014 Functional
HONEYWELL S8600H1022 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8600H1048 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8600H1055 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8600H1063 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8600H1071 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8600H1089 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8600H1097 Functional
HONEYWELL S8600H1105 Functional
HONEYWELL S8600M1005 Functional
HONEYWELL S8600M1013 Functional
HONEYWELL S8610B1007 Functional  
HONEYWELL S8610B1015 Functional
HONEYWELL S8610C1005 Functional
HONEYWELL S8610F1024 Functional
HONEYWELL S8610F1032 Functional
HONEYWELL S8610H1004 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8610H1012 Functional
HONEYWELL S8610H1020 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8610H1038 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8610H1046 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8610H1053 Functional
HONEYWELL S8610H1061 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8610H1079 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8610M1003 Functional
HONEYWELL S8610M1011 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S8610M1029 Functional
HONEYWELL S8610U1003 Functional
HONEYWELL S8620H1002 Functional
HONEYWELL S8620H1028 Functional
HONEYWELL S8660D1002 Functional
HONEYWELL S8670D1000 Functional
HONEYWELL S8670D1018 Functional
HONEYWELL S8670E1007 Functional
HONEYWELL S86B1007 Functional  
HONEYWELL S86B1015 Functional  
HONEYWELL S86B1031 Functional  
HONEYWELL S86C1007 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S86C1015 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S86C1023 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S86C1031 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S86C1049 Functional
HONEYWELL S86C1056 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S86D1005 Functional
HONEYWELL S86D1013 Functional
HONEYWELL S86D1021 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S86E1016 Functional
HONEYWELL S86E1093 Functional
HONEYWELL S86G1008 Functional
HONEYWELL S86G1016 Functional
HONEYWELL S86G1024 Functional
HONEYWELL S86G1032 Functional
HONEYWELL S86G1057 Functional
HONEYWELL S86G1073 Functional
HONEYWELL S86H1006 Functional
HONEYWELL S86H1014 Functional
HONEYWELL S86H1022 Functional
HONEYWELL S86H1048 Functional
HONEYWELL S86H1089 Functional
HONEYWELL S86H1097 Functional
HONEYWELL S86H1105 Functional
HONEYWELL S86H1113 Functional
HONEYWELL S86H1121 Functional
HONEYWELL S86H1139 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S86H1147 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S90B1003 Functional Lockout timing on replacement is 60 seconds.
HONEYWELL S90B1011 Functional Lockout timing on replacement is 60 seconds.
INTERNATIONAL 00018-03940 Functional
JOHNSON CONTROLS CSA49A-600R Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS CSA49A-601R Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS CSA49A-605R Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS CSA51A-601R Functional
JOHNSON CONTROLS CSA52A-600R Functional
JOHNSON CONTROLS G600AX-2 Functional
JOHNSON CONTROLS G600AX-3 Functional
JOHNSON CONTROLS G600KX-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G600LX-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G600LX-2 Functional
JOHNSON CONTROLS G600LY-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G600MX-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G600NX-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G600RX-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60AAG-2 Functional
JOHNSON CONTROLS G60AAG-7 Functional
JOHNSON CONTROLS G60CAG-1 Functional
JOHNSON CONTROLS G60CAG-2 Functional
JOHNSON CONTROLS G60CAG-3 Functional
JOHNSON CONTROLS G60CAG-4 Functional
JOHNSON CONTROLS G60CAG-6 Functional
JOHNSON CONTROLS G60CAG-7 Functional
JOHNSON CONTROLS G60CAG-8 Functional
JOHNSON CONTROLS G60CAG-9 Functional
JOHNSON CONTROLS G60CBG-2 Functional
JOHNSON CONTROLS G60CBG-3 Functional
JOHNSON CONTROLS G60CBG-4 Functional
JOHNSON CONTROLS G60CBG-5 Functional
JOHNSON CONTROLS G60CBG-6 Functional
JOHNSON CONTROLS G60CBG-7 Functional
JOHNSON CONTROLS G60CBG-8 Functional
JOHNSON CONTROLS G60CBG-9 Functional
JOHNSON CONTROLS G60PFH-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60PFH-2 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60PFL-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60PML-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60PVL-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60QAG-1 Functional
JOHNSON CONTROLS G60QAG-3 Functional
JOHNSON CONTROLS G60QAK-1 Functional
JOHNSON CONTROLS G60QBK-2 Functional
JOHNSON CONTROLS G60QBK-3 Functional
JOHNSON CONTROLS G60QCG-1 Functional
JOHNSON CONTROLS G60QFL-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60QGH-1 Functional
JOHNSON CONTROLS G60QHL-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60QHL-2 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60QJL-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60QLK-1 Functional
JOHNSON CONTROLS G60QRH-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60QRH-2 Functional
JOHNSON CONTROLS G60QRH-3 Functional
JOHNSON CONTROLS G60QRL-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60QSL-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60QTH-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60QTL-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60QUL-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60RGL-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60RHL-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60RSL-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G60ZAG-1 Functional
JOHNSON CONTROLS G60ZAG-2 Functional
JOHNSON CONTROLS G65BLG-1 Functional
JOHNSON CONTROLS G65DBM-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G65DBM-2 Functional
JOHNSON CONTROLS G65DBM-3 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G65DCM-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G65DFM-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G65DKM-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G65DLM-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G65QBM-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G65QBM-3 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G66MG-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G66MG-2 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G66NG-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G670AW-1 Functional
JOHNSON CONTROLS G670AW-2 Functional
JOHNSON CONTROLS G67AG-10 Functional
JOHNSON CONTROLS G67AG-11 Functional
JOHNSON CONTROLS G67AG-3 Functional
JOHNSON CONTROLS G67AG-4 Functional
JOHNSON CONTROLS G67AG-7 Functional
JOHNSON CONTROLS G67AG-8 Functional
JOHNSON CONTROLS G67AG-9 Functional
JOHNSON CONTROLS G67BG-2 Functional
JOHNSON CONTROLS G67BG-3 Functional
JOHNSON CONTROLS G67BG-4 Functional
JOHNSON CONTROLS G67BG-5 Functional
JOHNSON CONTROLS G67KG-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G67LG-1 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G67MG-1 Functional
JOHNSON CONTROLS G67MG-2 Functional
JOHNSON CONTROLS G67MG-3 Functional
JOHNSON CONTROLS G67MG-4 Functional
JOHNSON CONTROLS G67NG-2 Functional Lockout timing on replacement is 60 seconds.
JOHNSON CONTROLS G67NG-4 Functional
JOHNSON CONTROLS G770KGA-1 Functional
JOHNSON CONTROLS G770KHA-1 Functional
JOHNSON CONTROLS G770KHA-2 Functional
JOHNSON CONTROLS G770LGA-1 Functional
JOHNSON CONTROLS G770LGA-2 Functional
JOHNSON CONTROLS G770LGC-1 Functional
JOHNSON CONTROLS G770LGC-2 Functional
JOHNSON CONTROLS G770LGC-3 Functional
JOHNSON CONTROLS G770LGC-4 Functional
JOHNSON CONTROLS G770LHA-1 Functional
JOHNSON CONTROLS G770LHA-2 Functional
JOHNSON CONTROLS G770MGA-1 Functional
JOHNSON CONTROLS G770MGA-2 Functional
JOHNSON CONTROLS G770MGA-3 Functional
JOHNSON CONTROLS G770MGC-1 Functional
JOHNSON CONTROLS G770MGC-2 Functional
JOHNSON CONTROLS G770MGC-3 Functional
JOHNSON CONTROLS G770MGC-4 Functional
JOHNSON CONTROLS G770MGC-5 Functional
JOHNSON CONTROLS G770MGC-5 Functional
JOHNSON CONTROLS G770MHA-1 Functional
JOHNSON CONTROLS G770MHA-2 Functional
JOHNSON CONTROLS G770NGA-1 Functional
JOHNSON CONTROLS G770NGC-4 Functional
JOHNSON CONTROLS G770NGC-5 Functional
JOHNSON CONTROLS G770NGC-6 Functional
JOHNSON CONTROLS G770NGC-7 Functional
JOHNSON CONTROLS G770NHA-1 Functional
JOHNSON CONTROLS G770RGA-1 Functional
JOHNSON CONTROLS G770RHA-1 Functional
JOHNSON CONTROLS G770RHA-1 Functional
JOHNSON CONTROLS G775RGA-1 Functional
JOHNSON CONTROLS G775RHA-1 Functional
JOHNSON CONTROLS G775RHA-2 Functional
JOHNSON CONTROLS G779LHA Functional
JOHNSON CONTROLS Y79ABC-1 Functional
JOHNSON CONTROLS Y79ABC-2 Functional
JOHNSON CONTROLS Y79ABC-3 Functional
JOHNSON CONTROLS Y79ABC-4 Functional
JOHNSON CONTROLS Y79ABC-5 Functional
JOHNSON CONTROLS Y79ABC-6 Functional
JOHNSON CONTROLS Y79ABC-7 Functional
JOHNSON CONTROLS Y79ABD-1 Functional
JOHNSON CONTROLS Y79ABD-2 Functional
JOHNSON CONTROLS Y79BBA-1 Functional
JOHNSON CONTROLS Y79BBA-2 Functional
JOHNSTONE SUPPLY L37-705 Exact
JOHNSTONE SUPPLY L37-705 Functional
JOHNSTONE SUPPLY L37-839 Exact
KOOL-FIRE 98203 Functional
LEEMCO 14301 Functional
LENNOX INDUSTRIES 100-00831-03 Exact
LENNOX INDUSTRIES 100-831-01 Functional
LENNOX INDUSTRIES 100-831-03 Functional
LENNOX INDUSTRIES 18G9101 Exact
LENNOX INDUSTRIES 34G6601PR Exact
LENNOX INDUSTRIES 38E94 Exact  
LENNOX INDUSTRIES 97H041 Functional
LENNOX INDUSTRIES 97HO40 Exact
ROBERTSHAW 100-00834-41 Exact  
ROBERTSHAW 100-802-02 Exact
ROBERTSHAW 100-831-02 Functional
ROBERTSHAW 100-831-13 Functional
ROBERTSHAW 100-831-52 Functional
ROBERTSHAW 100-831-55 Functional
ROBERTSHAW 100-831-56 Exact
ROBERTSHAW SJ4 Functional
ROBERTSHAW SJ4001-100 Functional
ROBERTSHAW SJ4001-200 Functional
ROBERTSHAW SJ4001-201 Functional
ROBERTSHAW SJ4001-204 Functional
ROBERTSHAW SJ4001-250 Functional
ROBERTSHAW SJ4001-254 Functional
ROBERTSHAW SJ4001-400 Functional
ROBERTSHAW SJ4001-4001 Functional
ROBERTSHAW SJ4001-450 Functional
ROBERTSHAW SJ4001-4501 Functional
ROBERTSHAW SJ4001-454 Functional
ROBERTSHAW SJ4001-4541 Functional
ROBERTSHAW SJ4002-154 Functional
ROBERTSHAW SJ4002-254 Functional
ROBERTSHAW SJ4007-154 Functional
ROBERTSHAW SJ4007-2001 Functional
ROBERTSHAW SJ4007-204 Functional
ROBERTSHAW SJ4007-254 Functional
ROBERTSHAW SJ4007-400 Functional
ROBERTSHAW SJ4007-4001 Functional
ROBERTSHAW SJ4507-2501 Functional
ROBERTSHAW SJ4M1 Functional
ROBERTSHAW SP735A Functional  
ROBERTSHAW SP845-NU-3-C Exact  
UNI-LINE 63356 Exact Uni-Line UPC number. Number may appear preceded by Uni-Line's vendor i.d. number, 662013.ex. 66201312345.
UNI-LINE 63540 Exact Uni-Line UPC number. Number may appear preceded by Uni-Line's vendor i.d. number, 662013.ex. 66201312345.
UNI-LINE 63549 Exact Uni-Line UPC number. Number may appear preceded by Uni-Line's vendor i.d. number, 662013.ex. 66201312345.
UNI-LINE 780-737 Exact
UNI-LINE 780-737 Functional
UNI-LINE 780-764 Exact
UNI-LINE 780-766 Exact
W.W. GRAINGER 4E959 Exact
WESTWARD 668-501 Functional